Fluke 374 FC 600A TRMS Clamp Meter
R21 442,50
Fluke 374 FC 600A TRMS Clamp Meter. AC Current via Jaw: 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100–500 Hz)Crest Factor: 2.5 @ 600 A (Add 2% for CF > 2); AC Current via iFlex Probe: Up to 2500 AResolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)Accuracy: 3% ±5 digits (5–500 Hz)Crest Factor: 2.5 @ 1400 A, 1.42 @ 2500 A (Add 2% for CF > 2); DC Current: 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits. Product code: TTESDM374.
Description
Shop the Fluke 374 FC 600A TRMS Clamp Meter at Peculiar Beauté in South Africa. Use the product specifications below to compare this item with your equipment and project requirements.
Fluke 374 FC 600A TRMS Clamp Meter: product details
The listed ac current via jaw is 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100–500 Hz)Crest Factor: 2.5 @ 600 A (Add 2% for CF > 2). The listed ac current via iflex probe is Up to 2500 AResolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)Accuracy: 3% ±5 digits (5–500 Hz)Crest Factor: 2.5 @ 1400 A, 1.42 @ 2500 A (Add 2% for CF > 2). The listed dc current is 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits.
Choosing the right item
Compare the stated measurement range, connections and listed test function with the equipment and test requirements. Check the included components and any operating requirements. Match the exact product specification to your task before ordering, since items with similar names can serve different purposes or use different connections.
This item belongs to our electrical test tools range. Review its product code and listed measurements when comparing similar options. Furthermore, check the required accessories before completing your order.
Technical specifications
- AC Current via Jaw: 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100–500 Hz)Crest Factor: 2.5 @ 600 A (Add 2% for CF > 2)
- AC Current via iFlex Probe: Up to 2500 AResolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)Accuracy: 3% ±5 digits (5–500 Hz)Crest Factor: 2.5 @ 1400 A, 1.42 @ 2500 A (Add 2% for CF > 2)
- DC Current: 600.0 AResolution: 0.1 AAccuracy: 2% ±5 digits
- AC Voltage: 1000 VResolution: 0.1 V (≤600 V), 1 V (≤1000 V)Accuracy: 1.5% ±5 digits (20–500 Hz)
- DC Voltage: 1000 VResolution: 0.1 V (≤600 V), 1 V (≤1000 V)Accuracy: 1% ±5 digits
- mV DC: Range: 500.0 mVResolution: 0.1 mVAccuracy: 1% ±5 digits
- Resistance: Up to 6000 ΩResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω)Accuracy: 1% ±5 digits
- Capacitance: Up to 1000 µFResolution: 0.1 µF (≤100 µF), 1 µF (≤1000 µF)Accuracy: 1% ±4 digits
- Continuity Detection: Yes (≤30 Ω)
- Maximum Voltage to Ground: 1000 V
- Temperature Range: Operating: -10 °C to +50 °CStorage: -40 °C to +60 °C
- Operating Humidity: ≤90% RH (10–30 °C)≤75% RH (30–40 °C)≤45% RH (40–50 °C)
- Altitude: Operating: 3000 mStorage: 12,000 m
- Size (L × W × H): 249 × 85 × 45 mm
- Weight: 395 g
- Jaw Opening: 34 mm
- Flexible Probe Diameter: 7.5 mm
- Flexible Probe Cable Length: 1.8 m
- Battery Type: 2 × AA (NEDA 15A / IEC LR6)
- Safety Ratings: IEC 61010-1, Pollution Degree 2IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
- IP Rating: IP30 (non-operating)
- EMC / RF Compliance: IEC 61326-1, IEC 61326-2-2, CISPR 11 Class A, FCC 47 CFR 15 (exempt), Korea KCC Class A
- Temperature Coefficient: Add 0.1 × specified accuracy per °C above 28 °C or below 18 °C
- Position Sensitivity (iFlex): Distance from optimum:A: ±0.5% @ 12.7 mm (i2500-10), 35.6 mm (i2500-18)B: ±1.0% @ 20.3 mm / 50.8 mmC: ±2.0% @ 35.6 mm / 63.5 mm
Use and care
Follow the product and equipment instructions for connection, testing and interpretation. Inspect the working components before use and apply the method specified for the exact item. Read the relevant instructions before the first use. In addition, choose protective equipment that suits the task and working environment.
Package information
- Package Weight (kg): 0.395000
- Package Length (cm): 24.9
- Package Width (cm): 8.5
- Package Height (cm): 4.5
Before you order
First, compare the exact product code with the item you need. Check whether the name describes a single component, a pack or a complete kit. Next, review the listed size and connection details. Choose compatible parts for your existing equipment, since matching a brand alone does not confirm a fit. Package measurements describe the packed item rather than its working capacity. Finally, check the inclusion notes for separately sold accessories. Keep these details with your order information so you can identify the same item when replacing or expanding your equipment.
Order the Fluke 374 FC 600A TRMS Clamp Meter from Peculiar Beauté. Before checkout, compare the specifications and product photos with your requirements. Keep the product code TTESDM374 available if you need to identify this item again.
Additional information
| Weight | 0,395 kg |
|---|---|
| Dimensions | 24,9 × 8,5 × 4,5 cm |






Reviews